Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) intermittent pilot ignition modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers and other heating appliances.
- Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances
- Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed.
- For use with natural or LP gas
- Includes remote reset, automatic vent damper plug
- For use in single rod or dual rod/remote sense applications
- Supply voltage: 24V